Electrified locks
SL1/SK1 Electrified Ligature-resistant Trims
- The SL1/SK1 Electrified Ligature-resistant trim are specifically designed with multiple safety facets to reduce the risk of injury or death due to ligature strangulation.
Ask about thisText us about thisBack to electrified locks
Features
- Ligature-resistant designs positively contribute to healing environments - lever style is also ADA compliant
- Tested and certified to ANSI/BHMA Grade 1 operational and security standards
- UL listed for 3-hour fire door; spring-loaded fusible link inside lock case provides fail secure mode in case of fire
- Available lead lining for use in X-ray or other rooms with radiation concern
- Deadbolt functions include anti-saw pin in bolt to prevent cut-through
- Lock monitoring options include request to exit (RX), latchbolt (LX), door postion (DPS), and deadbolt (DM) (availability varies by function)
- Patented Everest 29 S123 keyway is provided standard which prohibits unauthorized key duplication
- Restricted geographically exclusive Primus upgraded security options offer advanced key control and exceptional physical security
- Smooth, sloped surface design with concealed fastening
- Available in 630 Satin Stainless Steel finish with an antimicrobial coating option
- Deadbolt functions also feature a ligature-resistant thumbturn
- Low holding current produces minimal heat, eliminating "hot levers" in electrically locking applications
- Quiet, motorized activation
- See HSLR ligature-resistant mortise trim for other designs in health care solutions
Specifications
- Case: Cold Rolled Steel (CRS) with corrosion resistant zinc dichromate plating
- Case size: 4-7/16" x 6 1/16" x 1" (113 mm x 154 mm x 25 mm)
- Spacing: knob or lever to cylinder 3-7/8" (98 mm); knob or lever to thumbturn hub 2-11/16" (68 mm)
- Door thickness: 1-3/4" (44 mm) standard
- Field reversible handing
- Lever and knob designs made of stainless steel
- Dimensions: SL1 3-7/32" x 6-1/8" x 3-1/8" (83 mm x 155 mm x 80 mm); SK1 3-3/16" x 3-3/16" x 2-5/16" (81 mm x 81 mm x 58 mm); thumbturn 2-11/16" x 2-11/16" x 1-3/32" (69 mm x 69 mm x 28 mm)
- Available 1/8" thick lock case lead lining option for use in X-ray or other rooms with radiation concern
- Backset: 2-3/4" (70 mm) only
- Armor: Standard - 1-1⁄4" x 8" x 7⁄32" (32 mm x 203 mm x 6 mm); Optional - 1-1⁄16" x 8" x 7⁄32" (27 mm x 203 mm x 6 mm)
- Deadbolt: 1" (25 mm) throw stainless steel
- Latch: 3⁄4" (19 mm) throw stainless steel with anti-friction tongue
Certifications
- ANSI/BHMA A156.13-2017 Series 1000, Grade 1 operational and security
- With FSIC interchangeable core cylinders: Grade 1 operational, Grade 2 security
- With SFIC interchangeable core cylinders: Grade 1 operational, Grade 3 security
- Complies with ICC A117.1 Accessible and Usable Buildings and Facilities (lever only)
- UL 10C and CAN/ULC-S104 listed 3-hour fire door (except L9076 and L9077) A label single doors, 4' x 10' and pairs 8' x 10'
- Letter F and UL symbol on latch front indicate listing
- UL 437 listed when using Primus high-security UL 437 cylinder
- UL 294 access control performance levels Destructive attack, Level 1
Available as
Details
- Supplied
- With the doors and frames, as one package
- Keying
- Keyed to your system
- Prep
- Doors and frames machined in our shop to fit
- Installed
- By our own installers