Electrified locks
HSLR Electrified Ligature-resistant Cylindrical Trim
- High Security Ligature Resistant Trim on the ND Series cylindrical chassis is made for behavioral health patient protection and is offered in two functions.
Ask about thisText us about thisBack to electrified locks
Features
- Provides a high level of ligature-resistance in an ADA compliant solution to positively contribute to healing environments
- Exceeds ANSI/BHMA Grade 1 operational and security standards
- UL listed for 3-hour fire door
- Vandlgard option allows the outside lever to rotate freely to prevent damage from excessive force while in a locked state
- Lead lining for use in X-ray or other rooms with radiation concern
- Patented Everest 29 S123 keyway is provided standard which prohibits unauthorized key duplication
- Restricted geographically exclusive Primus upgraded security options offer advanced key control and exceptional physical security
- Available in 630 Satin Stainless Steel finish
- ADA compliant - "no pinch, no grasp"
- Quiet, motorized activation
- Keyed storeroom function with Vandlgard option and non-keyed exit lock function
- Universal input voltage auto detects 12V or 24V DC
- Low maximum current draw allows multiple locks on a single power supply
- Energy-efficient low holding current
Specifications
- Chassis: Zinc and steel components plated for corrosion resistance
- Door thickness: 1-3/4" (44 mm) standard
- Specify handing with order
- Crescent style handle design in cast stainless steel
- Large plate escutcheon: 6.17" x 8.48" (152 mm x 335 mm x 8 mm); cast brass
- Handle projection from door is 3.01" (58 mm)
- Backset: 2-3/4" (70 mm) standard; 2-3/8", 3-3/4", and 5" optional
- 2-3/4" backset anti-friction fire door latch optional
- Faceplate: square corner 1-1⁄8" x 2-1/4" (29 mm x 57 mm) standard; square corner 1" x 2-1/4" (25 mm x 57 mm) for 2-3/8" backset doors
- Latchbolt: 1/2" (13 mm) throw oil impregnated stainless steel standard; 3/4" throw anti-friction bolt for pair doors optional
- Strike: ANSI curved lip strike 1-1⁄4" x 4-7⁄8" (32 mm x 124 mm) standard; T-strike with box and T-strike with deep box for fire door latch optional
- Strike lip length: 1-3⁄16" (30 mm) standard; extended lip strikes - 1-3⁄8" and 1-1/2" optional
Certifications
- ANSI A156.2-2011 Series 4000, Grade 1
- ANSI A156.25 (indoor)
- Patient Safety Standards, Materials and Systems Guidelines Recommended by the New York State Office of Mental Health
- Complies with ICC A117.1 Accessible and Usable Buildings and Facilities
- UL/cUL listed 3-hour fire door 3-hour fire doors: A label single doors 4' x 10' and pair doors 8' x 8' with 3/4" latch option
- 90-minute fire doors: 8' x 10' with 3/4" latch option
- Letter F and UL symbol on latch front indicate listing
- UL 437 listed when using Primus high-security UL 437 cylinder
Available as
Details
- Supplied
- With the doors and frames, as one package
- Keying
- Keyed to your system
- Prep
- Doors and frames machined in our shop to fit
- Installed
- By our own installers
Made by Schlage